home *** CD-ROM | disk | FTP | other *** search
/ HPAVC / HPAVC CD-ROM.iso / CELLP.ZIP / NEC01.TXT < prev    next >
Text File  |  1993-04-11  |  3KB  |  85 lines

  1. NEC P300
  2.  
  3. NOTES:  This unit is available in single and quad NAM versions
  4.         The ESN prefix is 135 decimal & 87 hex.
  5.         An NEC programing adaptor must be used to program these units.
  6.         NEC: 1-800-421-2141
  7.  
  8. NAM programing:
  9.  
  10. 1.  Determine if you have a single NAM or quad NAM unit:  Press FCN 3 2,
  11.     quad NAM units will display "NAM 1", 2, 3 or 4 and the phone number,
  12.     single NAM units will display the phone number only.
  13.  
  14. 2.  Later units follow a slightly different procedure, these are identified
  15.     by an ESN greater than (13500)839600
  16.  
  17. ACCESSING PROGRAMING MODE ON SINGLE NAM UNITS:
  18.  
  19. 1.  With the power off connect the NEC programing adaptor (part# MPS-A-3576).
  20.  
  21. 2.  Turn power on.
  22.  
  23. 3.  Press RCL # 7 1.
  24.  
  25. 4.  Press # to increment and store each step.
  26.  
  27. 5.  At any time press and hold CLR to complete and exit programing.
  28.  
  29. ACCESSING PROGRAMING MODE ON QUAD NAM UNITS WITH AN ESN LESS THAN 13500 839601
  30.  
  31. 1.  With the power off connect the NEC programing adaptor (part# MPS-A-3576)
  32.  
  33. 2.  Turn power on.
  34.  
  35. 3.  (Optional) Press RCL # 7 6 N #, where N=0 (NAM 1), N=1 (NAM 2),
  36.     N=2 (NAM 3).
  37.  
  38. 4.  Press RCL # 7 1.
  39.  
  40. 5.  Press # to increment and store each step.
  41.  
  42. 6.  At any time press and hold CLR to complete and exit programing.
  43.     Repeat steps 3 through 5 to program other NAMs if required.
  44.  
  45. ACCESSING PROGRAMING MODE ON QUAD NAM UNITS WITH AN ESN GREATER THAN
  46. 13500 839600
  47.  
  48. 1.  With the power off connect the NEC programing adaptor (part# MPS-A-3576)
  49.  
  50. 2.  Turn power on.
  51.  
  52. 3.  Press RCL # 0 1 to enter test mode.
  53.  
  54. 4.  (Optional) Press RCL # 7 6 N #, where N=0 (NAM 1), N=1 (NAM 2),
  55.     N=2 (NAM 3).
  56.  
  57. 5.  Press RCL # 7 1
  58.  
  59. 6.  Press # to increment and store each step.
  60.  
  61. 7.  At any time press and hold CLR to return to test mode.
  62.     Repeat steps 4 through 6 to program other NAMs if required.
  63.  
  64. 9.  From test mode press RCL # 0 2 to complete and exit programing.
  65.  
  66.  
  67. PROGRAMING DATA
  68.  
  69. STEP#    #OF DIGITS/RANGE    DISPLAY        DESCRIPTION
  70.  
  71. 01       10 DIGITS           Phone No.      MIN (AREA CODE & TEL#)
  72. 02       4 DIGITS            Lock Code      LOCK CODE
  73. 03       00000 - 32767       Home Area      SYSTEM ID
  74. 04       2 DIGITS            G.I. Mark      GROUP ID (10 IN USA)
  75. 05       0333 OR 0334        First P-CH     INITIAL PAGING CHANNEL
  76. 06       0 OR 1              Sys Select     PREFERRED SYSTEM (0=B, 1=A)
  77. 07       2 DIGITS            ACCOLC         ACCESS OVERLOAD CLASS
  78. 08       0 OR 1              MIM Mark       MIN MARK
  79. 09       0 OR 1              Local Use      LOCAL USE MARK
  80. 10       3 DIGITS            EMG No         EMERGENCY NUMBER (911)
  81.  
  82. LOCK & UNLOCK: F 6 four digit code then press 1 and scroll with volume keys to
  83. select: Normal, PL (Partial Lock), FL (Full Lock), press STO to store.
  84.  
  85. SYSTEM SELECT: F 5 3 then volume or */# to scroll, STO to store..